Rack Air Removal Unit SX100-240V 50/60HZ f.600mm

Part# ACF400
EAN:7330381702716

APC - Rack fan kit - for P/N: AR3106SP, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, SRT1000RMXLI, SRT1000RMXLI-NC

 
Out of Stock

Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.

Product specifications

Product Description APC - rack fan kit
Product Type Rack fan kit
Designed For P/N: AP7950B, AR3106SP, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBPD0160A, NBWL0355A, NBWL0356A, SMC15002U-BR, SMC1500I2U-BR, SMC1500I-2UC, SMT3000I2U-BR, SMX2000LVNCUS, SMX2000LVUS, SMX3000HV-BR, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVUS, SRT1000RMXLI, SRT1000RMXLI-NC, SRT1500RMXLA-NC

General features

Product Type Rack fan kit

Compatible with

Designed For P/N: ACCS1000, ACCS1001, ACCS1002, ACCS1003, ACCS1004, ACCS1005, ACDC1016, ACDC1017, ACDC1019, ACDC1020, ACDC2513, AP5017, AP5602, AP5606, AP5607, AP5616, AP7555, AP7562J, AP7701X298, AP7841, AP7852, AP7854, AP7857, AP7867, AP7894, AP7911, AP7940, AP7941, AP7950, AP7950B, AP7951, AP7952, AP7953, AP7954, AP7957, AP7961, AP7961X364, AP7991, AP92200, AP9290, AP9571, AR2900, AR2901, AR3000, AR3100, AR3100CTO, AR3100G, AR3100SP, AR3100SP1, AR3100SP2, AR3100TAA, AR3100-TU, AR3100W, AR3100X487, AR3100X609, AR3100X610, AR3100X617, AR3101, AR3106SP, AR3107, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3200, AR3300, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3307, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3810, AR3812, AR7007, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, DLA1500RM2U, NBPD0160A, NBPD0171, NBWL0355A, NBWL0356A, SBATTBLK, SC250RM1U, SC250RMI1U, SMC15002U-BR, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMT3000I2U-BR, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200R2HVNC, SMX3000HV-BR, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVUS, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT1500RMXLA, SRT1500RMXLA-NC, SU1400RMXLB3U, SU3000RMJ3U3W, SU3000RMJ3UOS3, SU5000R5TBXFMR, SUA1500R2X138, SUA2200R2X106, SUA2200R2X147, SUA2200R3XLNETPKG, SUA2200RMXL3U, SUA2200RMXLI3U, SUA3000R2IX38, SUA3000R2X180, SUA3000R2X428, SUA3000R3XLNETPKG, SUA3000RMXL3U, SUA3000RMXL3U-BR, SUA750R2X122, SUA750R2X338, SURT10000RMXLT, SURT10000RMXLT-2TF5, SURT3000RMXLI, SURT3000RMXLT, SURT3000RMXLT-1TF5, SURT5000RMXLI, SURT5000RMXLT, SURT5000RMXLT-1TF5, SURT5000XLIX438, SURT6000RMXLT, SURT6000RMXLT-1TF5, SURT7500RMXLI, SURT7500RMXLT, SURT7500RMXLT-1TF5, SURT7500XLJ-2TF4, SURT8000RMXLT, SURT8000RMXLT-1TF5, SURTA1500RMXL, SURTA2000RMXL, SURTA2000RMXL2U, SURTA3000RMXL, SURTD3000RMXLT, SURTD3000RMXLT-1TF5, SURTD5000RMXLT, SURTD5000RMXLT-1TF5, SYH2K6RMJ-TF3

Specifications

High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control. This space-saving solution mounts to the back of either the NetShelter SX or VX enclosure, requiring zero U space.

  • Ventilatorafskærmning
    En sikkerhedsforanstaltning, der giver beskyttelse mod ventilatoråbningen ved at dække indløbet.
  • Komponenter, der kan udskiftes på stedet
    Ventilatorer og elektronikmodul kan nemt udskiftes uden at afmontere enheden.
  • Øget kapacitet
    Højere varmefjernelseshastighed gør det muligt at installere mere udstyr i hvert rack.
  • Justerbar monteringsramme
    Rammen kan monteres på Netshelter SX- eller VX-kabinetter og kan udvides, så den passer til 42U, 47U eller 48U rackhøjder.
  • Fejltolerant blæsersystem
    I tilfælde af en blæserfejl vil de(n) resterende blæser(e) fortsætte med at køre.
  • LCD-skærm
    Alfanumerisk display, der viser systemparametre og alarmer.
  • Overvågning af temperatur
    Ændringer i temperaturen rapporteres via brugergrænsefladen eller e-mail.
  • Udstødningssystem med kanaler
    Fjerner varm luft fra datacentret for at forhindre gencirkulation og eliminere luftblanding.
  • Nul "U"-løsning
    Monteres på bagsiden af racket, så der er værdifuld rackplads til andet udstyr.
  • Dobbelt A-B strømindgange
    Trækker strøm fra UPS"en til strømbeskyttelse med dobbelte tilførsler til redundans.
New Retail

Neuwaren sind Produkte, die wir direkt von führenden IT-Herstellern kaufen. Wir kaufen und verkaufen hauptsächlich Laptops, PCs, Server / Storage, Monitore und Tablets. DCC kauft große Mengen von New Retail-Produkten, die zusammen mit der ursprünglichen Herstellergarantie in der Originalverpackung weiterverkauft werden.

 