Rack Air Removal Unit SX100-240V 50/60HZ f.600mm
Part# ACF400
EAN:7330381702716
APC - Rack fan kit - for P/N: AR3106SP, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, SRT1000RMXLI, SRT1000RMXLI-NC
Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.
Product specifications
Product Description | APC - rack fan kit |
Product Type | Rack fan kit |
Designed For | P/N: AP7950B, AR3106SP, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBPD0160A, NBWL0355A, NBWL0356A, SMC15002U-BR, SMC1500I2U-BR, SMC1500I-2UC, SMT3000I2U-BR, SMX2000LVNCUS, SMX2000LVUS, SMX3000HV-BR, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVUS, SRT1000RMXLI, SRT1000RMXLI-NC, SRT1500RMXLA-NC |
General features
Product Type | Rack fan kit |
Compatible with
Designed For | P/N: ACCS1000, ACCS1001, ACCS1002, ACCS1003, ACCS1004, ACCS1005, ACDC1016, ACDC1017, ACDC1019, ACDC1020, ACDC2513, AP5017, AP5602, AP5606, AP5607, AP5616, AP7555, AP7562J, AP7701X298, AP7841, AP7852, AP7854, AP7857, AP7867, AP7894, AP7911, AP7940, AP7941, AP7950, AP7950B, AP7951, AP7952, AP7953, AP7954, AP7957, AP7961, AP7961X364, AP7991, AP92200, AP9290, AP9571, AR2900, AR2901, AR3000, AR3100, AR3100CTO, AR3100G, AR3100SP, AR3100SP1, AR3100SP2, AR3100TAA, AR3100-TU, AR3100W, AR3100X487, AR3100X609, AR3100X610, AR3100X617, AR3101, AR3106SP, AR3107, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3200, AR3300, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3307, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3810, AR3812, AR7007, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, DLA1500RM2U, NBPD0160A, NBPD0171, NBWL0355A, NBWL0356A, SBATTBLK, SC250RM1U, SC250RMI1U, SMC15002U-BR, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMT3000I2U-BR, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200R2HVNC, SMX3000HV-BR, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVUS, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT1500RMXLA, SRT1500RMXLA-NC, SU1400RMXLB3U, SU3000RMJ3U3W, SU3000RMJ3UOS3, SU5000R5TBXFMR, SUA1500R2X138, SUA2200R2X106, SUA2200R2X147, SUA2200R3XLNETPKG, SUA2200RMXL3U, SUA2200RMXLI3U, SUA3000R2IX38, SUA3000R2X180, SUA3000R2X428, SUA3000R3XLNETPKG, SUA3000RMXL3U, SUA3000RMXL3U-BR, SUA750R2X122, SUA750R2X338, SURT10000RMXLT, SURT10000RMXLT-2TF5, SURT3000RMXLI, SURT3000RMXLT, SURT3000RMXLT-1TF5, SURT5000RMXLI, SURT5000RMXLT, SURT5000RMXLT-1TF5, SURT5000XLIX438, SURT6000RMXLT, SURT6000RMXLT-1TF5, SURT7500RMXLI, SURT7500RMXLT, SURT7500RMXLT-1TF5, SURT7500XLJ-2TF4, SURT8000RMXLT, SURT8000RMXLT-1TF5, SURTA1500RMXL, SURTA2000RMXL, SURTA2000RMXL2U, SURTA3000RMXL, SURTD3000RMXLT, SURTD3000RMXLT-1TF5, SURTD5000RMXLT, SURTD5000RMXLT-1TF5, SYH2K6RMJ-TF3 |
Specifications
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control. This space-saving solution mounts to the back of either the NetShelter SX or VX enclosure, requiring zero U space.
- Ventilatorafskærmning
En sikkerhedsforanstaltning, der giver beskyttelse mod ventilatoråbningen ved at dække indløbet. - Komponenter, der kan udskiftes på stedet
Ventilatorer og elektronikmodul kan nemt udskiftes uden at afmontere enheden. - Øget kapacitet
Højere varmefjernelseshastighed gør det muligt at installere mere udstyr i hvert rack. - Justerbar monteringsramme
Rammen kan monteres på Netshelter SX- eller VX-kabinetter og kan udvides, så den passer til 42U, 47U eller 48U rackhøjder. - Fejltolerant blæsersystem
I tilfælde af en blæserfejl vil de(n) resterende blæser(e) fortsætte med at køre. - LCD-skærm
Alfanumerisk display, der viser systemparametre og alarmer. - Overvågning af temperatur
Ændringer i temperaturen rapporteres via brugergrænsefladen eller e-mail. - Udstødningssystem med kanaler
Fjerner varm luft fra datacentret for at forhindre gencirkulation og eliminere luftblanding. - Nul "U"-løsning
Monteres på bagsiden af racket, så der er værdifuld rackplads til andet udstyr. - Dobbelt A-B strømindgange
Trækker strøm fra UPS"en til strømbeskyttelse med dobbelte tilførsler til redundans.